Main rules to respect are good practices in term of:
- Application and pump calibration,
- Weather anticipation
- Liquid antioxidant temperature control.
Liquid application practices:
Before initial use, pump calibration should be performed at the same temperature as that of the intended liquid application. It is essential to record the liquid temperature and document it in the calibration report. Whenever there is a change in temperature, recalibrate the pump accordingly. Regularly monitor antioxidant consumption as per established guidelines.
Always apply liquid antioxidants at the originally specified temperature, typically within the range of 20ºC to 30ºC.
Anticipate weather conditions changes and possible impact on liquid antioxidants temperature:
It is essential to maintain consistent control and monitoring of the liquid antioxidant temperature both prior to and during application. Temperature sensors are tipically used in the antioxidant Intermediate Bulk Container (IBC), drum, or bidon, while certain flowmeters can also relay temperature data. All collected information can be managed via a Programmable Logic Controller (PLC) or directly through connected technologies such as Kemin sciORIANTM (3). This system enables real-time collection of data including temperature, flow rate, quantity administered, bulk and stock levels, and pump status. Operators actively oversee temperature and application in real time. Should any issues arise, such as temperature reduction or pump failure, alert notifications are sent by email. All data is recorded to ensure full traceability.
Prior to installing a new IBC, drum, or Jerrycan, it is important to verify the temperature. As a standard procedure, allow the container to acclimate for several days near the existing antioxidant liquid. If required, gently warm the container to reach the desired temperature.
Temperature control from the IBC to the nozzle application point with alarms:
As mentioned above, it’s crucial to maintain the right liquid antioxidant temperature in the IBC/Drum/Jerrycan, in the suction line and in the pump, but also up to the nozzles.
For antioxidants’ temperature management, specific heated containers with temperature control or heating jackets with thermostat are used. For the last one, some internal temperature sensors are recommended to avoid overheating, especially when temperatures are increasing in spring[DB1] .
Sometimes nozzles application points are located at more than 15m of the pumps. In this case, pipes can go outside the plants or in cold areas. We suggest equipping along pipes with some heating tracer for maintaining a constant temperature. Higher temperature improves the antioxidant dispersion, mixing and efficacy.